Model Name |
70KTLC-Pro |
75KTLC-Pro |
80KTLC-Pro |
90KTLC-Pro |
100KTLC-Pro |
110KTLC-Pro |
Input |
|
Max. DC input power |
105kW |
112.5kW |
120kW |
135kW |
150kW |
165kW |
Max. DC input voltage |
1100V |
Max. DC input current |
40/40/20A |
40/40/20A |
40/40/20A |
40/40/20A |
40/40/20A |
40/40/20A |
MPPT voltage range |
200-1000V |
Recommended MPPT operating voltage |
600V |
Starting voltage |
180V |
No.Of MPPT |
6 |
8 |
Max. no.of strings per MPPT |
2 |
Output |
|
Rated output power |
70kW |
75kW |
80kW |
90kW |
100kW |
110kW |
Max. output power |
77kW |
82.5kW |
88kW |
99kW |
110kW |
121kW |
Max. output current |
112A |
121A |
128A |
144A |
160A |
176A |
Rated grid voltage |
400Vac |
Grid voltage range |
310~480Vac |
Rated grid frequency |
50Hz/60Hz |
Grid frequency range |
45~55Hz/55~65Hz |
THD |
<2% (Under the rated power) |
Power factor |
0.99 (Under the rated power) / Adjustable range: 0.8 leading~0.8 lagging |
DC current injection |
<0.5% (Under the rated power) |
System data |
|
Max. efficiency |
98.60% |
98.60% |
98.60% |
98.60% |
98.70% |
98.70% |
Euro. efficiency |
98.10% |
98.10% |
98.10% |
98.10% |
98.10% |
98.20% |
Humidity range |
0-100% non-condensing |
Cooling type |
Intelligent forced air cooling |
Temperature range |
-25~+60°C |
Power consumption at night |
<1W |
Max. working altitude |
4000m |
Display |
LED(optional: LCD) |
Communication interface |
WIFI(optional: RS485 or GPRS) |
Protection |
|
DC reverse-polarity protection |
Yes |
Short circuit protection |
Yes |
Output over current protection |
Yes |
Output over voltage protection |
Yes |
Insulation resistance monitoring |
Yes |
Residual current detection |
Yes |
Surge protection |
Yes |
Grid monitoring |
Yes |
Islanding protection |
Yes |
Temperature protection |
Yes |
Integrated DC switch |
Yes |
Mechanical data |
|
Dimensions (WHD) |
1160*611*286mm |
Weight |
92kg |
Protection class |
IP66 |
Standard |
|
Safety standard/EMC standard |
NB/T32004-2018, IEC62109, IEC61000, IS16169 & IS16221(BIS) |
Grid-connected standard |
IEC61727, EN50549-1, VDE-4105, NRS-097-2-1, OVE-Richtlinie R25, UNE217001/2, Ordinance No.140 |
Other standard |
IEC61683, IEC62116, EN50530, IEC60068 |